Eigenschaften

  • Bi-directional DC source and load
  • High configuration flexibility
  • Scalable from 12 to 252kW with 40 ,120 or 600V
  • Regenerativer Wirkungsgrad der an das Wechselstromnetz zurückgesendeten Entladungsleistung größer als 90%
  • Current, Voltage & Mode Transitions <1 mSec
  • Eingebaute digitale Messungen mit Diagramm- und Zielfernrohranzeigen
  • Batterie-Emulationsmodus
  • Touch Panel, LabVIEW® & IVI Drivers
  • Enerchron® Test Executive
Hochleistungs-Batterieladung Entladungstestsystem der Serie 9200

Anwendungen

NHR?s Regenerative 9200 Battery Test System includes expandable power ranges from 12kW modules up to 252 kW with 40,120 or 600V bi-directional DC loads. This battery cycler provides optimal configuration that enables companies the flexibility to expand power levels as needed. It addresses the evolving battery test requirements for electric vehicles, renewable energy storage and critical power applications. NHR?s battery test systems are used as battery cyclers, regenerative, bidirectional DC sources, regenerative DC loads, high power DC sources, or Battery / DC emulators.

The 9200 Battery Test System is ideally suited for applications where maximum battery test system configuration flexibility is needed to cover a broad range of battery voltage, current and power requirements now and in the future. Key differentiating features from other battery cyclers on the market include flexible control options, modular and scalable power, fast transients, built-in safety, and ease of use. We also offer comprehensive battery test systems solutions that include battery test software for easy test program creation and enterprise battery test lab management.

Vorteile

  • Batterie-Emulation mit OCV & Serienwiderstand
  • Entwickelt zum Testen und Emulieren aller Batteriechemikalien
    - Automatische Energieintegration (vollständiger und halber Zyklus)
    - Mehrere Sicherheitsschichten zum Schutz des Prüflings
  • Software-Tools zur Verkürzung der Testentwicklungszeit
    - PC-basierte Softpanel-Benutzeroberfläche mit Diagramm
    - Mitgelieferte LabVIEW- und IVI-C / IVI-COM-Treiber
    - Optional: Enerchron® Testsequenzer

Leistungen

  • Regenerativ: Gibt mehr als 901 TP1 Strom an die Anlage zurück, wodurch erhebliche elektrische Einsparungen erzielt werden.
  • Modular - Vollfunktionstester pro Kanalaufbau
  • Parallelen für Hochleistungstests (bis zu 144 kW)
  • Sicher simulieren und emulieren? Reale Welt? Bedingungen
    - Übergangszeiten für Spannung, Strom und Modi unter mS
    - Emulieren Sie über / unter geladene Batterien
    - Emulieren Sie sicher BMS & Batteriefehler
  • Flexible Konfiguration (3 beliebige Module pro System)

Einzelne Testkanalspezifikationen

Power Module Versionen Modell 4904 Modell 4912 Modell 4924 Modell 4960
Umschlag aufladen 0-40 V, 600 A, 8 kW 0-120 V, 200 A, 8 kW 0-240 V, 100 A, 8 kW 0-600 V, 40 A, 8 kW
Entladungsumschlag 1,2-40 V, 600 A, 12 kW 4-120 V, 200 A, 12 kW 6-240 V, 100 A, 12 kW 10-600 V, 40 A, 12 kW
UUT-Verbindung Buss Bar Anderson EBC A32 Anderson EBC A32 Anderson SB75X
Stromspannung 40V 120V 240v 600V
Meßgenauigkeit 0,051 TP1 + 20 mV 0,051 TP1 + 60 mV 0,051 TP1 + 120 mV 0,051 TP1 + 0,3 V
Genauigkeit einstellen 0,1% + 40 mV 0,1% + 120 mV 0,11 TP1 + 240 mV 0,1% + 0,6V
Auflösung 0,005% (2 mV) 0,005% (6 mV) 0,005% (12 mV) 0,005% (30 mV)
Strom (pro Modul) 600A 200A 100A 40A
Meßgenauigkeit 0,1% + 0,6A 0,1% + 0,2A 0,1% + 0,1A 0,1% + 40 mA
Genauigkeit einstellen 0,2% + 1,2A 0,2% + 0,4A 0,2% + 0,2A 0,2% + 80 mA
Auflösung 0,005% (30 mA) 0,005% (10 mA) 0,005% (5 mA) 0,005% (2 mA)
Leistung (pro Modul)
Reichweite (Gebühr) 8kW 8kW 8kW 8kW
Reichweite (Entladung) 12kW 12kW 12kW 12kW
Meßgenauigkeit 0,3% + 36W 0,3% + 36W 0,3% + 36W 0,3% + 36W
Genauigkeit einstellen 0,4% + 48W 0,4% + 48W 0,4% + 48W 0,4% + 48W
Auflösung 0,005% (0,6 W) 0,005% (0,6 W) 0,005% (0,6 W) 0,005% (0,6 W)
Serienwiderstand
Reichweite 0-33? 0-100? 0-200? 0-500?
Genauigkeit einstellen 2% 2% 2% 2%
Körperlich
Größe (HxBxT) 72 x 28 x 31"/1829 x 711 x 787mm
Gewicht 669 kg

Downloads

Ressourcen

Datenblatt
App Hinweis: Die Grundlagen des Batterietests
Webinar: Get Your Battery Project Back On Track in 2021
Webinar: Battery Module/Pack Test Requirements
EV-Batterien - NH Research (NHR)

Testing Applications

Battery Test:

  • EV/ESS Battery Module/Pack Test
  • Start - Stop Test
  • Battery Characterization
  • Cycling, Life-cycle
  • Charge, Discharge
  • Fuel Cell Test-Module, Stack

Battery Emulation:

  • EV Powertrain, Avionics Propulsion Systems
  • DC Charger
  • Power Conversion: DC/DC Converters, Inverters
  • On-board Charger, UPS, Power Distribution Unit (PDU)
  • Microgrid, ESS, PV Emulation

The Power of Choice: Multiple Control Options

The ability for a battery test system to interface with and control an entire test environment is critical. Engineers need to have multiple ways to control the battery test instrument. Depending on the specific need, an engineer may 1) choose to have direct access to the drivers for in-house programming, 2) choose to use an integrator, or 3) choose NHR?s Enerchron® Test Executive software solution.

All NHR battery test systems can be easily integrated into existing test platforms or as the power stage for new test platforms. To achieve this, NHR provides fully documented drivers using either IVI or SCPO languages along with examples, applications, and integration support. NHR also has a number of integration partners who are familiar with our hardware and can deliver a full turn key test system. These integrators develop fully custom systems using your specified hardware sensors and fixturing components.

Chart: Flexible Control & Integration
Flexible control & integration
Battery Testing Two Types of Batteries - NH Research (NHR)

Modular & Scalable Power

The 9200 Battery Test System is highly configurable and can parallel up to 21 power modules that can test multiple batteries with different test programs and start/stop times!

For example, on a battery test system configured with three power modules, one of the power modules could test a 12kW battery, while the other two modules could be paralleled to test a 24kW battery. Both batteries could have different battery parameters set and tested at the same time. The end result is an extraordinarily flexible battery test system that makes battery module/pack testing more effective and efficient.

Schnelle Reaktionszeiten

Voltage and current transitions, or slew rates, of the test system must be faster than the battery under test to emulate real-world settings. Our systems have fast response times and command speeds to accurately emulate real-world conditions through the hardware and software.

Slow rise-time of typical DC supply
Sub-millisecond rise time of NHR

Built-in, Multiple Layers of Safety

When it comes to testing new battery technologies, safety is vital. NHR solutions provide mulitple layers of hardware and software protection. The combination of safety contactors, reverse polarity checker, and pre-charge circuitry are built-in automatically to the hardware and easy to control in a single solution. There are no hidden fees or added costs, and safety is designed into the product versus being an afterthought. All of these safety mechanisms are controlled and fully integrated into the automation system, providing full safety control throughout the test enviornment.

Diagram: 9300 Integrated Safety Features
All Included, Plus Additional Multiple Layers of Safety
Programmable Safety Limits

Comprehensive Battery Test Solutions

We?re your partner in test. We provide comprehensive battery test solutions for the entire product life cycle. We have solutions and in-house application experts that can help you at any design or manufacturing stage whether you?re at the R&D engineering or high volume manufacturing stages.

Testimonial

“The NHR 9200 battery test systems are flexible, reliable and cost effective. The ability to configure single 9200s, or multiple 9200s, for either multiple low power channels or a single high power channel gives us greater flexibility and efficiency in our test scheduling.”

This flexibility has allowed us to perform more of our testing in-house saving us time and money. The power ratings and voltage range of the 9200s allow us to fulfill all of our module, 48V pack and 12V pack testing requirements.

NHR test equipment is very dependable. Our testing requires 24/7 operation and the NHR units have done this with zero downtime. The slew rate capability of the units allows us meet the response-demand and accuracy of our customer drive cycles as well as giving us the capability of performing some specialty testing in-house.

Verwandte Produkte

Have a Question Regarding Our Battery Test Systems?

Contact us today to learn how NHR can customize a test solution that fits your specific needs.