single channel battery charge discharge test system 9210 series

Click image for larger view

Single Channel Battery Test System – 9210 Series

Battery Test System for Automated Characterization Testing, Power Cycling Testing, Life-Cycle Testing & More!

Features

  • Smaller footprint makes it easier to move within a lab (roughly half the size of the 9200)
  • Custom waveform/profile generation
  • Sub-mS voltage, current & mode transition times
  • Built-in digital measurements with charting & scope displays
  • Internal controller with software & connections for an external monitor & keyboard
  • Expandable from 12 to 252kW with 40, 120, or 600V bi-directional DC loads
  • Regenerative, 87% efficiency of discharge power returned to AC mains
  • Multiple safety layers to protect battery being tested
  • Battery emulation & burn-in applications
  • Create, run, monitor, chart & report UUT profiles without writing any code

Quote Request

Applications

The 9210 further extends its 9200 family of high-power battery charge/discharge test systems, which are especially suitable for xEV electric vehicle and grid storage battery cycling as well as drive-cycle simulations and grid-energy simulations.

Like the successful 9200 systems, the new single module test system (9210) utilizes any of the 40V, 120V, or 600V modular, independent 12-kilowatt DC power modules which enable testing of a number of smaller batteries, each with a different test plan, power level and start/stop times. The smaller footprint makes it easier to move within a laboratory and/or manufacturing, allowing the tester to be brought to the engineer’s workspace.

Advantages

single channel battery charge discharge test system 9210 series

  • Battery emulation using OCV & series resistance
  • Designed for testing &mp: emulating all battery chemistries
    – Automatic energy integration (full & 1/2 cycle)
    – Multiple safety layers to protect UUT
  • Software tools to shorten test development time
    – PC-based Softpanel GUI with charting
    – Supplied LabVIEW & IVI-C/IVI-COM drivers
    – Optional: Enerchron® test sequencer

Benefits

  • Regenerative, returns greater than 87% of power to the facility, which provides significant electrical savings.
  • Modular – full function tester per channel design
  • Parallels for high power testing (up to 252kW)
  • Safely simulate and emulate “Real World” conditions
    – Sub-mS voltage, current, & mode transition times
    – Emulate over/under charged batteries
    – Safely emulate BMS & battery failures
  • Small footprint for easy movement

9210 Series Single Channel DC Test System Specifications

Model Number9210-49049210-49129210-4960
Programming Capability
Operating StatesCharge (Source), Discharge (Load), Standby, Battery
Charge/Discharge ModesConstant Voltage (CV), Current (CC), Power (CP), Resistance (CR)
Charging Envelope0-40V, 8kW, 600A0-120V, 8kW, 200A0-600V, 8kW, 40A
Discharging Envelope1-40V, 12kW, 600A4-120V, 12kW, 200A10-600V, 12kW, 40A
ProgrammingRngAccy1Res1RngAccy1Res1RngAccy1Res1
Voltage0-40V0.1%+0.1%0.005%0-120V0.1%+0.1%0.005%0-600V0.1%+0.1%0.005%
Current±600A0.21%+0.21%0.005%±200A0.21%+0.21%0.005%±40A0.21%+0.21%0.005%
Power±8/-12kW0.41%+0.41%0.005%±8/-12kW0.41%+0.41%0.005%±8/-12kW0.41%+0.41%0.005%
Resistance0-34Ω02%0.005%0-100Ω02%0.005%0-500Ω02%0.005%
Slew Rate   
  Voltage0.011V/s-80V/ms0.033V/s-240V/ms0.165V/s-600V/ms
  Current0.17A/s-3000A/ms0.55A/s-1000A/ms0.011A/s-40A/ms
  Resistance0.01Ω/s-34Ω/Ms0.28Ω/s-100Ω/Ms0.14Ω/s-500Ω/Ms
  Power2W/s-8kW/s2W/s-8kW/s2W/s-8kW/s
Test MeasurementRngAccy1Res1RngAccy1Res1RngAccy1Res1
Voltage, DC Avg0-40V0.05%+0.05%0.005%0-120V0.05%+0.05%0.005%0-600V0.05%+0.05%0.005%
Current, DC Avg, A-Hr0-600A0.1%+0.1%0.005%0-200A0.1%+0.1%0.005%0-40AV0.1%+0.1%0.005%
Power, Ah, kWh±12kW0.2%+0.2%0.005%±12kW0.2%+0.2%0.005%±12kW0.3%+0.2%0.005%
Time1ms-1Yr0.1%0.005%1ms-1Yr0.1%0.005%1ms-1Yr0.1%0.005%
1 All Accuracies are % os set + % of Range, all Resolutions are % of Range unless otherwise indicated. 2 Input Voltage set at placement of order.

More Info

single channel battery charge discharge test system 9210 series

Related Products

Application Testing

The 9210 Series Single Module Battery Test System is useful for testing the following products & applications:
Automatic Guided Vehicle (AGV) Testing, Battery Packs, Chargers, Electric Vehicles (EV), Electric Vehicles Supply Equipment (EVSE), Flow Batteries, Fuel Cells, In-Device Testing, Microgrid Testing, Pack Controllers 9v & 12v Batteries, Primary Battery Systems (Alkaline, Lithium), Redox Batteries, Secondary Battery Systems (Rechargeable, Lithium-Ion), Service Disconnects, Super Capacitors, Vehicle to Grid (V2G) Testing, Wire Harnesses

Share this: Facebooktwittergoogle_plusredditpinterestlinkedintumblrmailFacebooktwittergoogle_plusredditpinterestlinkedintumblrmail


NH Research, Inc. | 16601 Hale Ave., Irvine, CA 92606 NH Research, Inc. USA Website | Ph: (949) 474-3900 | Email: sales@nhresearch.com | NH Research, Inc. China Website nhresearch.com.cn